2018年9月18日星期二

What is an automated cell counter?

Cell counter is an machine which used in medical lab for counting blood cells,like ed cells, white cells and platelet condition,
automated cell counter means machine can finish all counting processes by machine itself,
please check automated cell counter operation video to see more.

From this video,
You can find the automated cell counter should work together with DILUENT, RINSE, LYSER reagent,

Diluent is to dilute blood samples, to keep the blood cell in original volume completely within a certain period and to guarantee pulse obtained corresponding to the cell volume by appropriate conductivity.
LYSER is For in vitro quantitative detection of white blood cells number in whole blood and hemoglobin concentration, etc.
RINSE is for daily washing
CONDENCE RINSE is for deep washing after your several usage for the machine.


                      automated cell counter reagent
 
After you finish the all process, it will print out one report.

                              automated cell counter report

According to the value of the reagent, it can be tested for different Diseases,
The diseases list can be tested by automated cell counter 
Any kind of Infections
Vitamin and mineral deficiencies
Thalassemia 
Bone marrow failure
Inflammation
Cancer
Effects of chemotherapy
Leukemia
Autoimmune conditions 
Abnormal development of bone marrow
Anemia
Dehydration, fluid loss
Effects of certain antibiotics
Effects of a number of medications 

If you want to know the price for different models ?
Please Click automated cell counter price to find more.

What else do you need to know about automated cell counter ?
Welcome to share to your doctors friends, and comment your questions on our blog,

2018年9月6日星期四

automated cell counter

Operation Video for automated cell counter,



Features for automated cell counter,:

Can be Open and Closed reagent System.
Open Reagent system will be suitable for any brand reagent, like Mindray, Beckmen and others.
Can be done OEM service, put your logo on the machine.
3-part differentiation of WBC, 23 parameters, single channel counter ,up to 35 samples test per hour
Volume measurement by time ,not wrong warning 
Adanced valve technology,long life
RS232 interface, PC connecting

Electrical resistance for counting and SFT method of hemoglobin
Low sample consumption : venous 9.8 ul, capillary 9.8 ul, pre-diluted 20 ul for twice testing one time 
8.4” color TFT, Windows interface all testing parameter displayed simultaneously
Windows operation system graphical buttons mouse and keyboard operation
Double convolution and intelligent fitting
Automatic diluting , Mixing , rinsing and clog clearing

Automatically sample probe cleaning (inside and outside)

Large storage capacity: up to 10,000 samples +3 histograms

Internal thermal-sensitive printer or external printer.

RS232 interface, PC connecting

Configuration,
Main Unit, 1 Pc

Main Technical Specifications for automated cell counter,
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode : Single Channel + unique Hemoglobin test system
Sample volume: 9.6μL for Venous and capillary mode, 20μL for pre-diluted mode
Throughput: More than 35 samples per hour, operate 24 hours a day, auto sleeping and waking-up functions
Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation langue: English, Chinese
QC control : X-B, L-J, X , SD, CV %
Reference Value Setting : Male , Female, Children, Neonate
Alarm : 25 test of alert messages
Input / output : RS232, parallel printer and keyboard
Print : Graphic thermal printer with various printing format,  optional external printer
Temperature : 18℃ - 30℃,wet ≤ 10-90%
Power supply : 220 V ±22 VAC, 50±1Hz
Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H )
Weight : 20 KG
 
Precision for automated cell counter.
Parameters                 linear range            CV %
WBC( 10 9 / L )              0.0 - 99.9              ≤2%
RBC ( 1012 / L )              0.0 - 9.99             ≤1.5%
MCV ( fL )                  40-150                ≤0.5%  
PLT ( 10 9 / L )              0-999                  ≤4.0%
HGB( g/L )                 0.0-300.0               ≤1.5%

Parameters for automated cell counter.
WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR
3 –histograms : WBC,RBC and PLT

Test Report Sample


 
Customers Reviews for automated cell counter,

Package for automated cell counter.,
Standard Blank carton package with foam protection for the machine.


If this automated cell counter model can't satisfy your request, please click following links to check more other models.







Contact Us Now, Get Discount Now,

2018年8月29日星期三

What is benchtop refrigerated centrifuge?

A centrifuge is a piece of equipment that use sedimentation principle, applying a force perpendicular to the axis of spin (outward) that can be very strong. 

What is benchtop refrigerated centrifuge?
Benchtop means it is small can be put into the table. it is not a floor stand type. you can put into your labroom table without much space. Refrigerated function can keep the sample as a requested temperature.

What is benchtop refrigerated centrifuge usage in Hospital Labroom?
Vaccuum Centrifuge can concentrates solutes from a liquid sample into a dry state or a wet pellet state. can be used in DNA, RNA, nucleotides, and other proteins.
hematocrit centrifuge is mainly used to determine the value of the blood hair cells, as well as the centrifuge of the micro blood and micro capacity.
Blood Bank Centrifuge is used for blood ,biochemistry, biological sample,It is a special centrifuge designed to satisfy the rapid centrifuge of blood banks.

(Blood Bank Centrifuge Rotator)

Main Point to choose benchtop refrigerated centrifuge and other centrifuge.
1.Machine Style
Tabletop, portable and Floor stand type,

          (Tabletop small mini centrifuge)
Tabletop is small to put into your table, it don't request a large space to put.

            (Tabletop centrifuge)
Portable type is very light and smaller than Tabletop one, it is more easy to bring it everywhere.
Floor stand type is always Large Capacity model, and request a space to put, it is better to ask the machine demision before you buy that.

           ​​​​​​​(Floor stand centrifuge)
if you only have small place to put this floor stand centrifuge.

2,Speed,
Normally we will separate all machine into Low speed(≤10000rpm) and High Speed(≥10000rpm), sometimes there will be other speed separation,
But you need to confirm with your doctor or your technical person that your application test requests how many rpm speed. 
this is the an important point

3,Refrigerated function,
Some special sample requests cool temperature during the centrifugation, then refrigerated centrifuge will be requested.

4,Application,
Different application will request for the different volume tubes and different speed, and other conditions,
so if you tell suppliers about your application, such as beauty, Hematocrit, Cell Smear and others, the supplier can suggest you suitable model according to their experience.


                                     (Centrifuge Rotator Example)
​​​​​​​
5,
Max Rotator quantity to use in the machine, and the Rotator tube volume(how many ml), different types are with different price.
When you choose one machine, you should consider your possible applications, and check if these machine can be optional suitable rotators for the future usage, even you don't buy these rotators now.
Different Machine can be optional different rotator.


Purchase suggestion,
Small hospitals can be equipped with benchtop refrigerated centrifuge because of the small workload and the small batch of secondary processing.

Large hospitals usually use Full Automatic Uncap Centrifuge to do vacuum blood collection and separation, but because of the use of vacuum blood collection capacity increased to 7ML, and the number of daily treatment is relatively large, usually choose a centrifugal and automatic cap removal machine, to reduce manual cap removal time to improve efficiency.


If you have any other suggestions about the centrifuge knowledges ?
Do you need an user manual of the centrifuges to know more about this machine?

welcome to commen or share our post to your friends, then ask it from our company.